Test Standard: CE Compliant. Compliance: Intended for use in measurements according to ASTM E 1021-15 , ASTM E948, IEC 60904-8, IEC 60904-1
Test Purpose:
Sciencetech PTS system conducts SR, EQE, IQE and IV measurements with user friendly software. The system includes a main xenon arc lamp, monochromator with automated order sorting filters, a steady-state solar simulator Class AAA bias light source ( only with PTS-2 ) measurement electronics, computer, and software required to measure solar cell characteristics. The system provides users with a light tight sample chamber for all measurements. Shielded and light tight test area enclosure has convenient removable cover allowing access from top, front and sides.
Applications: Photovoltaic Solar Cell Testing, IV Characterization, Spectral Response, External Quantum Efficiency-IPCE, Internal Quantum Efficiency (PTS2-IQE Model), Photoconductivity Measurement, Reflectance Measurements Capability.
Features: Spectral Range 250-2500 nm, Tunable Light Source, Source Measure Unit, Lock-in Amplifier, Light Tight Sample Chamber, User Selectable Bias Voltage, AC and DC Measurement Mode, Manually Controlled Shutter, SciPV software for full control of the system.
|
Measurement Capabilities
|
PTS 1 SR (175-9203)
|
PTS 2 QE/IPCE (175-9204)
|
PTS 2 IQE (175-9205)
|
|
Current-Voltage (IV) Testing
|
Measures VOC , ISC, Rshunt, Pmax, efficiency %, and fill factor
|
-
|
Included
|
Included
|
|
Spectral Response (SR)*
|
250 - 2500 nm scanning range
|
Included
|
Included
|
Included
|
|
External Quantum Efficiency (EQE)
|
Incident photon to converted electron ratio (IPCE)
|
Included
|
Included
|
Included
|
|
AC and DC measurement mode
|
Modulated / Continuous measurement capability
|
Included
|
Included
|
Included
|
|
Internal Quantum Efficiency (IQE)
|
The ratio of charge carriers collected by the cell to the number of photons absorbed by the cell
|
----
|
----
|
Included
300 - 1100 nm
|
Technical Specifications
|
Configuration Description
|
PTS 1 SR (175-9203)
|
PTS 2 QE/IPCE (175-9204)
|
PTS 2 QE+IQE (175-9205)
|
|
Tunable Light Source
|
· 150 W Xenon short arc lamp, 1200 hour lifetime
|
•
|
•
|
•
|
|
· 250 - 2500 nm tuning/scanning range (Xenon)
|
•
|
•
|
•
|
|
· 1/4 m Czerny-Turner monochromator with an adjustable bandpass of 0.4 to 48 nm with 600 l/mm grating , 0.2-24 nm with 1200 l/mm grating
|
•
|
•
|
•
|
|
· Motorized triple grating turret system (3 gratings included):
· 1200 l/mm blazed at 250 nm
· 1200 l/mm blazed at 500 nm
· 600 l/mm blazed at 1000 nm
|
•
|
•
|
•
|
|
· Adjustable beam size ( 0.5mm - 19 mm diameter with standard optics)
|
•
|
•
|
•
|
|
· Includes hard coated order sorting filters
|
•
|
•
|
•
|
|
Bias Light Source
|
· 150 W Xenon short arc lamp, average lifetime 1200 hours
|
-
|
•
|
•
|
|
· 25x25mm AAA, (ASTM E927-19) Solar Simulator
|
|
•
|
•
|
|
· Includes mounted AM1.5G filter + additional filter slot
|
-
|
•
|
•
|
|
Reference Detector
|
· Broadband pyroelectric detector with quartz window, Element diameter: 5 mm
|
•
|
•
|
•
|
|
· Calibrated range 250 - 2500 nm
|
•
|
•
|
•
|
|
Measurement System
|
· Source meter, maximum 30 W, 30 V, 1 A
|
•
|
•
|
•
|
|
· Voltage accuracy 30 µV and current accuracy 10 pA
|
•
|
•
|
•
|
|
· Measurement time period for 100 IV points is 20s
|
•
|
•
|
•
|
|
· Voltage bias user settable ±10 V capability
|
•
|
•
|
•
|
|
· Lock-in Amplifier
|
•
|
•
|
•
|
|
· Chopper 4 - 200 Hz
|
•
|
•
|
•
|
|
· Standard auto time constant feature
|
•
|
•
|
•
|
|
· Temperature control (10-60 °C) (1)
|
Accessory Available
|
Accessory Available
|
Accessory Available
|
|
· Ac and DC measurement mode
|
•
|
•
|
•
|
|
IQE Measurement System
|
· 50 mm integrating sphere
|
-
|
-
|
•
|
|
· Internal quantum efficiency measurement determined from material reflectance measurement (hardware included) 300 - 1100nm range.
|
-
|
-
|
•
|
|
Sample Placement
|
· 50 × 50 mm simple sample spacer for proper placement of the sample under the monochromatic and bias light beam. Includes simple electrical connections.
|
•
|
•
|
•
|
|
Software and Interface
|
· Modern software written in .NET (Windows 10/11 Operating System)
|
•
|
•
|
•
|
|
· Compatible with Windows 10/11, 32/64bit
|
•
|
•
|
•
|
|
· Data files and automation log exportable as ASCII
|
•
|
•
|
•
|
|
· Pre-configured and tested control computer included
|
•
|
•
|
•
|
|
· Built in microcontroller switches and monitors signals automatically
|
•
|
•
|
•
|
|
· 1 USB port
|
•
|
•
|
•
|
|
· 1 IEC 60320 C14 power entry inlet
|
•
|
•
|
•
|
|
Compliance
|
· Intended for use in measurements according to ASTM E 1021-15 , ASTM E948, IEC 60904-8, IEC 60904-1
|
•
|
•
|
•
|
|
Power system
|
· Single phase, configurable for 230 VAC, 50 Hz or 110 VAC, 60 Hz
|
•
|
•
|
•
|
量子效率系统
测试标准:CE 认证。符合 ASTM E 1021-15、ASTM E948、IEC 60904-8、IEC 60904-1。
测试目的:
Sciencetech PTS 系统通过用户友好软件进行 SR、EQE、IQE 和 IV 测量。系统包括主氙弧灯、带自动分序滤光片的单色仪、稳态 AAA 级偏置光源(仅 PTS-2)、测量电子设备、计算机和测量太阳能电池特性所需的软件。系统为用户提供全封闭的样品室。
应用领域:光伏太阳能电池测试、IV 特性分析、光谱响应、外量子效率(IPCE)、内量子效率(PTS2-IQE 型号)、光电导测量、反射测量。
特点:光谱范围 250-2500 nm,可调谐光源,源测量单元,锁相放大器,全封闭样品室,用户可选偏置电压,AC 和 DC 测量模式,手动控制快门,SciPV 软件全面控制系统。
技术规格:
|
配置描述
|
PTS 1 SR (175-9203)
|
PTS 2 QE/IPCE (175-9204)
|
PTS 2 IQE (175-9205)
|
|
可调谐光源
|
150 W 氙短弧灯,1200 小时寿命
|
•
|
•
|
|
|
250 - 2500 nm 调谐范围(氙灯)
|
•
|
•
|
|
|
1/4 米 Czerny-Turner 单色仪
|
•
|
•
|
|
|
电动三光栅转台系统(含 3 块光栅)
|
•
|
•
|
|
偏置光源
|
-
|
150 W 氙短弧灯,AAA 级太阳模拟器
|
•
|
|
参考探测器
|
宽带热电探测器,5 mm 直径
|
•
|
•
|
|
测量系统
|
源表,最大 30 W,30 V,1 A
|
•
|
•
|
|
IQE 测量系统
|
-
|
-
|
50 mm 积分球
|
|
软件与接口
|
.NET 软件(Windows 10/11)
|
•
|
•
|